The Fuego SCS Basic RF represents a new standard among laboratory gas burners. With its innovative design this laboratorygas burner is suitable for all flame related applications in the laboratory.
Simple and Safe Operation
The Fuego SCS basic RF can be operated with a wireless foot pedal or the button function. Three programs are available: flexible start-stop functions and the conventional foot pedal operation for short flame sterilization. The Fuego SCS basic RF is also suitable for connection to the fully automated innoculation loop carrousel autoloop Pro.
Flame Sterilizing with Button Function
WLD-TEC offers an additional alternative for safe flame sterilizing. With the button function the flame can be started and stopped easily by pushing the function knob.
Everything inside
The Fuego SCS basic RF represents the complete system of the new Wireless-Series “RF“. The modern radio operation is already integrated in the safety laboratory gas burner.
Top Rate Safety
The Safety Control System SCS demonstrates state-of-the-art safety technology which constantly analyzes potential hazards and, if necessary, initiates safety measures, such as an interruption of the gas supply. In addition to the ignition and flame control function and the overheating protection, the new safety concept also features continuous burner head control (BHC). BHC unfailingly identifies burner head clogging by liquids or solid substances and ensures the correct assembly of the burner head.
Exceptional passive safety features: After prolonged use, the residual heat display will signal that the burner head is still hot in order to protect the user from burns.
Modern Design
The unique shape is eye-catching. The Fuego SCS basic RF is extremely space-saving. Measurements: 103 x 49 x 130 mm (w x h x d). The low profile body facilitates ergonomic operation; the streamlined design reduces air flow disturbances in a clean room workbench to a minimum. Moreover, the Fuego SCS basic RF is very easy to clean - a laboratory gas burner without grooves and rough edges. Clogging is not an issue. Spilled liquids simply escape through an integrated drain while solid substances can easily be removed by opening the burner shaft. It is even possible to dismantle the individual components of the removable burner head for in-depth cleaning. With the DualKnob for adjusting gas and air flow, the flame can be precisely regulated.
Another Plus
Excellent energy efficiency reduces the gas consumption. This increases the burning time when gas cartridges are used.
Robust
Fabricated entirely of stainless steel and with fireproof controls the Fuego SCS basic RF can withstand extreme lab conditions.
Fuego SCS basic - Ideal for use in cleanroom workbenches and laboratories.
Technology | Microprocessor |
Programs Foot pedal: Button: | Standard (flame during pressed foot pedal) Start-Stop with timer, 60 min Start-Stop with timer, 60 min
|
Safety features Safety Control System (SCS) with gas safety cut off: | ignition and flame control, temperature monitor burner head clogging and assembly monitor (BHC) automatic unit switch off after 4h residual heat display
|
Gas supply and consumption Gas connection: Gas types: Connected load: Continuous cartridge operation: | 1/4” left with gas filter II2ELL3B/P: natural gas E/LL,18 - 25 mbar liquid gas, 47,5 - 57,5 mbar 70 g/h liquid gas; 95 l/h natural gas (LL) CV 360 - 40 min, Express 444 - 50 min, CG 1750 - 150 min, C 206 - 170 min, CP 250 - 210 min, CV 470 - 370 min
|
Temperatures Flame temperature: Temperature threshold level: | 1350 °C on liquid gas 1300 °C on natural gas (E) 1 kW liquid gas, 1kW natural gas
|
Electrical Power consumption: Power connection: | 2 VA (stand by max. 0.1 VA) 100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A Level 6 (stand by power consumption max. 0.1W)
|
Mechanical Casing and operating controls: Burner head: Cover of burner shaft: Measurements (w x h x d): Weight: | stainless steel / glass, UV and solvent resistant removable and decomposable, stainless steel Ø 23 mm, with drains 103 x 49 x 130 mm 700 g
|
Radio Frequency System Range: Frequency: Channels: Batteries foot pedal: Life time batteries (foot pedal): | Range: 2 - 5 m 2.4 GHz 253 2 x AA (Mignon) approx. 2000 hours (operation 8 hours per day: > 1 year)
|
Licenses DIN-DVGW Reg.-No.: CE: EU guidelines: | NG-2211AS0167 EN 61326-1, EN 61010-1, EN 61010-2-010 EN 301489, EN 300440-1, EN 300440-2 2014/30/EU, 2014/35/EU, 2011/65/EU, 2014/53/EU (RED)
|
The range including tools for a simple start-up of the Fuego SCS basic RF. Only in EU countries available.
- Safety laboratory gas burner Fuego SCS basic RF
with button function and stainless steel radio foot pedal (battery operated)
2 AA batteries (Mignon)
3 standard-programs for foot pedal and button function
SCS (Safety Control System) with BHC (Burner Head Control)
Removable and decomposable burner head
Holding device for 3 inoculation loop holders
Nozzles for natural gas, propane / butane gas
Instruction manual and 2-year warranty - Tilt mechanism, right / left
- Wrench 17 mm for gas connection
- Screwdriver for burner head and cover of burner shaft
- Switching power supply for global usage 100 - 240 V / 50/60 Hz (level 6)
- Different plugs for worldwide use
- Tubing connector with swivel nut
- Stainless steel radio foot pedal (battery operated) with 2 AA batteries (Mignon)
Gas-Safety Adapters, Tubes, Connectors, Cartridges